MULTI-TARGET COMBINATION OF RENEWABLE ENERGY SOURCES WITH THE OMAN SMART GRID AND ENERGY STORAGE SYSTEM / (Kayıt no. 288955)

MARC ayrıntıları
000 -BAŞLIK
Sabit Uzunluktaki Kontrol Alanı 03713nam a22002897a 4500
003 - KONTROL NUMARASI KİMLİĞİ
Kontrol Alanı KOHA
005 - EN SON İŞLEM TARİHİ ve ZAMANI
Kontrol Alanı 20230419103329.0
008 - SABİT UZUNLUKTAKİ VERİ ÖGELERİ - GENEL BİLGİ
Sabit Alan 221101d2022 cy ||||| m||| 00| 0 eng d
040 ## - KATALOGLAMA KAYNAĞI
Özgün Kataloglama Kurumu CY-NiCIU
Kataloglama Dili eng
Çeviri Kurumu CY-NiCIU
Açıklama Kuralları rda
041 ## - DİL KODU
Metin ya da ses kaydının dil kodu eng
090 ## - Yerel Tasnif No
tasnif no YL 2467
Cutter no A46 2022
100 1# - KİŞİ ADI
Yazar Adı (Kişi adı) Almesheikhi, Yousef Salim Ahmed
245 10 - ESER ADI BİLDİRİMİ
Başlık MULTI-TARGET COMBINATION OF RENEWABLE ENERGY SOURCES WITH THE OMAN SMART GRID AND ENERGY STORAGE SYSTEM /
Sorumluluk Bildirimi YOUSUF SALIM AHMED ALMESHEIKHI; SUPERVISOR: ASST. PROF. DR. MOEIN JAZAYERI
264 ## - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Date of production, publication, distribution, manufacture, or copyright notice 2022
300 ## - FİZİKSEL TANIMLAMA
Sayfa, Cilt vb. 99 sheets;
Boyutları 31 cm.
Birlikteki Materyal Includes CD
336 ## - CONTENT TYPE
Source rdacontent
Content type term text
Content type code txt
337 ## - MEDIA TYPE
Source rdamedia
Media type term unmediated
Media type code n
338 ## - CARRIER TYPE
Source rdacarrier
Carrier type term volume
Carrier type code nc
502 ## - TEZ NOTU
Tez Notu Thesis (MSc) - Cyprus International University. Institute of Graduate Studies and Research Electrical and Electronics Engineering Department
504 ## - BİBLİYOGRAFİ NOTU
Bibliyografi Notu Includes bibliography (sheets 89-95)
520 ## - ÖZET NOTU
Özet notu ABSTRACT<br/>Based on current available data, load, and climatic conditions, this thesis optimizes an<br/>integrated hybrid renewable energy system (PV-wind) in Sultanat of Oman (Thumrait<br/>area) in terms of efficiency and cost by designing of two systems, being on grid and offgrid<br/>systems. Thumrait is chosen because it has high yearly average wind speed of 6.45<br/>m/s as well as its average sun radiation of about 6.12 kWh/m2/day. In addition, projects<br/>of renewable energy request more lands than non-renewable projects, which the proposed<br/>city can handle. Several simulations are run for each case using (HOMER) software to<br/>generate the overall sizing strategy that is used for techno-economic evaluations. The first<br/>step is to determine the normal load profiles for the specified area. Similarly, the average<br/>daily (GHI) and wind speeds values for the proposed location are obtained from NASA<br/>through HOMER software (HOMER software, Resources).<br/>The optimal configuration for the first case, the off-grid system with PV cells, wind<br/>turbines, storage batteries, and a diesel generator, is optimized with 31,316 kW of PV<br/>capacity, nine wind turbines, 119 storage batteries, a total Net Present Cost of $<br/>108,051,100.00, and a levelized cost of energy, LCOE, of 0.103 $/KWh. The CO2<br/>emissions for this case is 2,426,483 kg per year. The second case study focuses on grid<br/>connected HRES, which comprises solar panels, wind turbines, and the possibility of<br/>adding a battery bank. In this scenario, the optimal HRES configuration has 113,785 kW<br/>of solar capacity and 22,500 kW of wind production (15WTs), with a cumulative value of<br/>Net Present Cost of $23,655,900.00 and an LCOE ($/KWh) of 0.00608. CO2 emissions<br/>totals 10,546,917 kg per year for this system. The hybrid grid-connected system has the<br/>lowest value of COE with 0.00608 $ and the lowest NPC based on the results of both offgrid<br/>and on-grid systems. This system arrangement's NPC and Initial Cost (IC) are<br/>23,655,900 $ and 114,794,170 $, respectively. The Initial Cost, on the other hand, is higher<br/>than that of an off-grid hybrid system (73.09 M$), and it is approximately one-and-a-half<br/>times that of an off-grid system. Thus, in the case of limited investment budget, the offgrid<br/>system is recommended, whereas the on-grid system is the best option for long-term<br/>investment. Regarding renewable fraction status, the two best designs generate a large<br/>percentage of RESs, greater than 95 percent, indicating that these systems are the most<br/>environmentally friendly.
650 #0 - KONU BAŞLIĞI EK GİRİŞ - KONU TERİMİ
Konusal terim veya coğrafi ad Renewable energy sources
Alt başlık biçimi Dissertations, Academic
650 #0 - KONU BAŞLIĞI EK GİRİŞ - KONU TERİMİ
Konusal terim veya coğrafi ad Wind turbines
Alt başlık biçimi Dissertations, Academic
700 1# - EK GİRİŞ - KİŞİ ADI
Yazar Adı (Kişi adı) Jazayeri, Moein
İlişkili Terim supervisor
942 ## - EK GİRİŞ ÖGELERİ (KOHA)
Sınıflama Kaynağı Dewey Onlu Sınıflama Sistemi
Materyal Türü Thesis
Mevcut
Geri Çekilme Durumu Kayıp Durumu Sınıflandırma Kaynağı Kredi için değil Koleksiyon Kodu Kalıcı Konum Mevcut Konum Raf Yeri Kayıt Tarih Source of acquisition Yer Numarası Demirbaş Numarası Son Görülme Tarihi Fatura Tarihi Materyal Türü Genel / Bağış Notu
    Dewey Onlu Sınıflama Sistemi   Tez Koleksiyonu CIU LIBRARY CIU LIBRARY Tez Koleksiyonu 01.11.2022 Bağış YL 2467 A46 2022 T2780 01.11.2022 01.11.2022 Thesis Electrical and Electronics Engineering Department
    Dewey Onlu Sınıflama Sistemi     CIU LIBRARY CIU LIBRARY Görsel İşitsel 01.11.2022 Bağış YL 2467 A46 2022 CDT2780 01.11.2022 01.11.2022 Suppl. CD Electrical and Electronics Engineering Department
Araştırmaya Başlarken  
  Sıkça Sorulan Sorular