PERFORMANCE ANALYSIS AND OPTIMIZATION OF AN ABSORPTION HEAT TRANSFORMER CYCLE INTEGRATED TO SEA WATER DESALINATION SYSTEM / BASHIR KOJOLO ABUBAKAR; SUPERVISOR: ASSOC. PROF. KEYVAN BAHLOULI

Yazar: Katkıda bulunan(lar):Dil: İngilizce 2023Tanım: ix, 51 sheets; 31 cm. Includes CDİçerik türü:
  • text
Ortam türü:
  • unmediated
Taşıyıcı türü:
  • volume
Konu(lar): Tez notu: Thesis (MSc) - Cyprus International University. Institute of Graduate Studies and Research Mechanical Engineering Department Özet: ABSTRACT The absorption heat transformer (AHT) systems are devices with the unique capability of raising the temperature of low or moderately warm waste heat sources to more useful levels. In the current work, an absorption heat transformer cycle operating with the water/lithium bromide mixture connected to a water desalination unit is studied. For the purpose of performance analysis and parametric study, the cycle is modeled in the Engineering Equation Solver (EES) software. Then, a parametric analysis is carried out on the system to study the effect of variation of some important design parameters on the considered system. Results of the parametric study show that the COP of the cycle highly depends on the outlet temperature of the absorber heat exchanger. Also, the COP of the cycle decreases by increasing temperature of the condenser. Furthermore, the cycle's COP is moderately increasing as the source temperature increases too. This is also found that the highest exergy destruction happens in the absorber. The amount of produced fresh water via desalination unit at the optimized condition is estimated as 0.1783 kg/s. Keywords: Absorption heat transformers, Desalination systems, Exergy analysis LiBr+H2O, Optimization
Materyal türü: Thesis
Mevcut
Materyal türü Geçerli Kütüphane Koleksiyon Yer Numarası Durum Notlar İade tarihi Barkod Materyal Ayırtmaları
Thesis Thesis CIU LIBRARY Tez Koleksiyonu Tez Koleksiyonu YL 2822 A38 2023 (Rafa gözat(Aşağıda açılır)) Kullanılabilir Mechanical Engineering Department T3171
Suppl. CD Suppl. CD CIU LIBRARY Görsel İşitsel YL 2822 A38 2023 (Rafa gözat(Aşağıda açılır)) Kullanılabilir Mechanical Engineering Department CDT3171
Toplam ayırtılanlar: 0

Thesis (MSc) - Cyprus International University. Institute of Graduate Studies and Research Mechanical Engineering Department

Includes bibliography (sheets 47-48)

ABSTRACT
The absorption heat transformer (AHT) systems are devices with the unique capability
of raising the temperature of low or moderately warm waste heat sources to more
useful levels. In the current work, an absorption heat transformer cycle operating with
the water/lithium bromide mixture connected to a water desalination unit is studied.
For the purpose of performance analysis and parametric study, the cycle is modeled in
the Engineering Equation Solver (EES) software. Then, a parametric analysis is carried
out on the system to study the effect of variation of some important design parameters
on the considered system. Results of the parametric study show that the COP of the
cycle highly depends on the outlet temperature of the absorber heat exchanger. Also,
the COP of the cycle decreases by increasing temperature of the condenser.
Furthermore, the cycle's COP is moderately increasing as the source temperature
increases too. This is also found that the highest exergy destruction happens in the
absorber. The amount of produced fresh water via desalination unit at the optimized
condition is estimated as 0.1783 kg/s.
Keywords: Absorption heat transformers, Desalination systems, Exergy analysis
LiBr+H2O, Optimization